Leave Your Message
Products Categories
Featured Products

EIfClip™ Reusable Clip Applier for Absorbable Ligating Clips - China Suppliers and Factory Solutions

Discover our premium range of products sourced directly from reliable suppliers in China. Our factory is committed to delivering high-quality items that meet international standards. By working closely with top manufacturers, we ensure that our offerings are not only innovative but also competitively priced. Explore the advantages of partnering with us, your trusted source for exceptional products made in China. With our extensive network of suppliers and efficient production processes, we are dedicated to providing you with the best solutions for your needs. Choose us for quality, reliability, and excellence in every order
  • Place of Origin Made in China
  • Brand Name EIfClip (TM) Reusable Clip Applier
  • Certification ISO13485
  • Model Number ECA-480K12、ECA-380K12、ECA-280K12

Product Features
For ligation of cystic duct, arterial vessels with diameter of 5mm or below.
Convenience: after cleaning and sterilization, there's no need to disassemble every part of the applier.
Security: 1. Compression closure mechanism may provide a more secure closure than latch closure mechanism, reducing the risk of tissue interposition; 2. No foreign matters left after surgery.
6  after
Product Description
Product Use: Used in laparoscopic surgery to deliver EIfClipTM Absorbable Hemostatic Ligation Clips. Product Highlights: It can be cleaned directly without disassembly after use, and the trigger can be activated with a locking buckle to prevent the wrong clamping.
Device Classification: [CN] Class II
[KR] Class I
Material: Stainless Steel, PPS, Silica Gel
Specification Description: ECA-480K12: shaft length of 480 mm
ECA-380K12: shaft length of 380 mm
ECA-280K12: shaft length of 280 mm
Storage Conditions: Store in a clean room with no more than 80% relative humidity, no corrosive gas, room temperature.
Product Specification
Instructions Check whether it is clean, sterilized and packed well before use, and must be operated by experienced medical staff, see the IFU for details.
Product advantages It can be cleaned directly without disassembly after use, and the trigger can be activated with a locking buckle to prevent the wrong clamping.
Product structure and composition Consists of proboscis, joint and handle. Proboscis is composed of a rotation shaft, a Ejector pin and a jaw with spring buckle. Joint is composed of rotating wheel, flushing valve and sealing cap, and the handle is composed of a fixing handle, a firing handle, an end cap, a lock button and a gill shaft screw.
Precautions
  • 1. The clip applier must be cleaned and disinfected in a timely manner after use, and the device is not required to be disassembled during the cleaning and disinfection process;
  • 2. Avoid using corrosive solution to clean and disinfect the applier; Avoid heavy pressure or impact on various components of the device;
  • 3. The clip applier shall keep the lock button in the locked state after cleaning and disinfection, and continuously maintain this state, so as to avoid causing early misfiring;
  • 4. This clip applier is only applicable to the Company’s absorbable ligating clip products;
  • 5. The product has no continuous firing function.
Maintenance Prior to daily use, check whether the firing handle moves smoothly, the lock button is normal, the ejector pin has no obvious deflection, the ejecting height meets the scale loop line, the rotating wheel operates smoothly, and the release button is normal.
Frequently Asked Questions
What is the primary application of this ligation clip applier?
It is used in laparoscopic surgery to deliver EIfClip™ Absorbable Hemostatic Ligation Clips, specifically designed for the ligation of the cystic duct and arterial vessels with a diameter of 5mm or below.
Do I need to disassemble the applier for cleaning and sterilization?
No, for convenience, there is no need to disassemble every part of the applier during the cleaning and sterilization process. It can be cleaned directly without disassembly.
What safety features does the applier offer?
It features a compression closure mechanism that provides a more secure closure than latch closure mechanisms, reducing the risk of tissue interposition. Additionally, it leaves no foreign matters after surgery and includes a locking buckle on the trigger to prevent accidental misfiring.
What materials are used to manufacture this medical device?
The clip applier is constructed from high-quality Stainless Steel, PPS (Polyphenylene Sulfide), and Silica Gel.
What are the recommended storage conditions?
The device must be stored at room temperature in a clean room with a relative humidity of no more than 80%, and in an environment free of corrosive gases.
Does this clip applier support continuous firing?
No, this clip applier does not have a continuous firing function. It is only applicable to the Company’s absorbable ligating clip products.